The Lync Chat Adapter connects to the Lync Proxy and registers for messages related to chat sessions.

Procedure 

  1. Launch the Recorder Manager and click General Setup > Integration Service > Settings > Create.

  2. Select Lync Chat Adapter.

  3. Enter the following settings:

    Field

    Description

    Adapter Name

    Type a unique name for this adapter. Do not use any special characters or characters that truncate xml. This field is not case sensitive.

    Description

    Optional: Type a description of the adapter.

    Adapter Type

    A read-only field that lists the adapter selected above.

    Startup Type

    Select a startup type: Automatic, Manual, or Disabled.

    DataSource

    Select an Application data source Third-party systems that provide data to the system, including employee and device states, and data change events. Typical data sources are phone switches, PBXs, or LANs. with a sub-type of Lync.

    Timespan for purging (hours)

    Specify a time, in hours, after which calls should be purged. If set to 6, for example, data older than 6 hours will be deleted. It cannot be recovered once purged.

    Time interval for triggering purging (minutes)

    Specify a time, in minutes, to indicate how often to check for data to be purged.

  4. Click Save.